{"id":9670,"date":"2023-03-21T09:03:44","date_gmt":"2023-03-21T09:03:44","guid":{"rendered":"https:\/\/www.ecgsa.com\/?post_type=project&p=9670"},"modified":"2023-03-21T09:03:44","modified_gmt":"2023-03-21T09:03:44","slug":"water-transmission-system-from-oxagon-to-gayal","status":"publish","type":"project","link":"https:\/\/www.ecgsa.com\/project\/water-transmission-system-from-oxagon-to-gayal\/","title":{"rendered":"Water Transmission System from OXAGON to GAYAL"},"content":{"rendered":"

1,200 MLD pumping station, sited at NEOM desalination plant tank farm, and a culverted twin 2,000 mm dia. carbon steel potable water transmission system.<\/p>\n

The pumping station discharges through a 65 km twin 2,000 mm dia. transmission system to the High Point Reservoir, while a 37 km similar gravity twin transmission system conveys water to Gayal.<\/p>\n

Future provision within the pumping station will enable the later addition of three further piping systems to give an overall capacity of 2,100 MLD.<\/p>\n

Full infrastructure and electrical sub-stations and support facilities are provided at the pumping station site. The 100 km buried pre-cast culvert is sized to accommodate a third future 2,000 mm dia. pipeline and includes connection chambers, washout, and air release facilities.<\/p>\n

The scope includes system hydraulics, surge\/transient analysis and protection measures, and full instrumentation and control.<\/p>\n","protected":false},"featured_media":9672,"template":"","activity":[556,567,557,558,568,559,561,566],"country":[171],"scope":[699,695,786,675],"sector":[256,259],"yoast_head":"\nWater Transmission System from OXAGON to GAYAL - ECG website<\/title>\n<meta name=\"description\" content=\"1,200 MLD pumping station, sited at NEOM desalination plant tank farm, and a culverted twin 2,000 mm dia. carbon steel potable water transmission system.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ecgsa.com\/project\/water-transmission-system-from-oxagon-to-gayal\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Water Transmission System from OXAGON to GAYAL - ECG website\" \/>\n<meta property=\"og:description\" content=\"1,200 MLD pumping station, sited at NEOM desalination plant tank farm, and a culverted twin 2,000 mm dia. carbon steel potable water transmission system.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ecgsa.com\/project\/water-transmission-system-from-oxagon-to-gayal\/\" \/>\n<meta property=\"og:site_name\" content=\"ECG website\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ecgsa.com\/app\/uploads\/2023\/03\/1679389328_306_214645_1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1100\" \/>\n\t<meta property=\"og:image:height\" content=\"520\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.ecgsa.com\/project\/water-transmission-system-from-oxagon-to-gayal\/\",\"url\":\"https:\/\/www.ecgsa.com\/project\/water-transmission-system-from-oxagon-to-gayal\/\",\"name\":\"Water Transmission System from OXAGON to GAYAL - ECG website\",\"isPartOf\":{\"@id\":\"https:\/\/www.ecgsa.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.ecgsa.com\/project\/water-transmission-system-from-oxagon-to-gayal\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.ecgsa.com\/project\/water-transmission-system-from-oxagon-to-gayal\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.ecgsa.com\/app\/uploads\/2023\/03\/1679389328_306_214645_1.jpg\",\"datePublished\":\"2023-03-21T09:03:44+00:00\",\"dateModified\":\"2023-03-21T09:03:44+00:00\",\"description\":\"1,200 MLD pumping station, sited at NEOM desalination plant tank farm, and a culverted twin 2,000 mm dia. carbon steel potable water transmission system.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.ecgsa.com\/project\/water-transmission-system-from-oxagon-to-gayal\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.ecgsa.com\/project\/water-transmission-system-from-oxagon-to-gayal\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.ecgsa.com\/project\/water-transmission-system-from-oxagon-to-gayal\/#primaryimage\",\"url\":\"https:\/\/www.ecgsa.com\/app\/uploads\/2023\/03\/1679389328_306_214645_1.jpg\",\"contentUrl\":\"https:\/\/www.ecgsa.com\/app\/uploads\/2023\/03\/1679389328_306_214645_1.jpg\",\"width\":1100,\"height\":520,\"caption\":\"1,200 MLD pumping station, sited at NEOM desalination plant tank farm, and a culverted twin 2,000 mm dia. carbon steel potable water transmission system. The pumping station discharges through a 65 km twin 2,000 mm dia. transmission system to the High Point Reservoir, while a 37 km similar gravity twin transmission system conveys water to Gayal. Future provision within the pumping station will enable the later addition of three further piping systems to give an overall capacity of 2,100 MLD. Full infrastructure and electrical sub-stations and support facilities are provided at the pumping station site. The 100 km buried pre-cast culvert is sized to accommodate a third future 2,000 mm dia. pipeline and includes connection chambers, washout, and air release facilities. The scope includes system hydraulics, surge\/transient analysis and protection measures, and full instrumentation and control.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.ecgsa.com\/project\/water-transmission-system-from-oxagon-to-gayal\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.ecgsa.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Projects\",\"item\":\"https:\/\/www.ecgsa.com\/project\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Water Transmission System from OXAGON to GAYAL\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.ecgsa.com\/#website\",\"url\":\"https:\/\/www.ecgsa.com\/\",\"name\":\"ECG website\",\"description\":\"Just another WordPress site\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.ecgsa.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"}]}<\/script>\n","yoast_head_json":{"title":"Water Transmission System from OXAGON to GAYAL - ECG website","description":"1,200 MLD pumping station, sited at NEOM desalination plant tank farm, and a culverted twin 2,000 mm dia. carbon steel potable water transmission system.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ecgsa.com\/project\/water-transmission-system-from-oxagon-to-gayal\/","og_locale":"en_US","og_type":"article","og_title":"Water Transmission System from OXAGON to GAYAL - ECG website","og_description":"1,200 MLD pumping station, sited at NEOM desalination plant tank farm, and a culverted twin 2,000 mm dia. carbon steel potable water transmission system.","og_url":"https:\/\/www.ecgsa.com\/project\/water-transmission-system-from-oxagon-to-gayal\/","og_site_name":"ECG website","og_image":[{"width":1100,"height":520,"url":"https:\/\/www.ecgsa.com\/app\/uploads\/2023\/03\/1679389328_306_214645_1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.ecgsa.com\/project\/water-transmission-system-from-oxagon-to-gayal\/","url":"https:\/\/www.ecgsa.com\/project\/water-transmission-system-from-oxagon-to-gayal\/","name":"Water Transmission System from OXAGON to GAYAL - ECG website","isPartOf":{"@id":"https:\/\/www.ecgsa.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.ecgsa.com\/project\/water-transmission-system-from-oxagon-to-gayal\/#primaryimage"},"image":{"@id":"https:\/\/www.ecgsa.com\/project\/water-transmission-system-from-oxagon-to-gayal\/#primaryimage"},"thumbnailUrl":"https:\/\/www.ecgsa.com\/app\/uploads\/2023\/03\/1679389328_306_214645_1.jpg","datePublished":"2023-03-21T09:03:44+00:00","dateModified":"2023-03-21T09:03:44+00:00","description":"1,200 MLD pumping station, sited at NEOM desalination plant tank farm, and a culverted twin 2,000 mm dia. carbon steel potable water transmission system.","breadcrumb":{"@id":"https:\/\/www.ecgsa.com\/project\/water-transmission-system-from-oxagon-to-gayal\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ecgsa.com\/project\/water-transmission-system-from-oxagon-to-gayal\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.ecgsa.com\/project\/water-transmission-system-from-oxagon-to-gayal\/#primaryimage","url":"https:\/\/www.ecgsa.com\/app\/uploads\/2023\/03\/1679389328_306_214645_1.jpg","contentUrl":"https:\/\/www.ecgsa.com\/app\/uploads\/2023\/03\/1679389328_306_214645_1.jpg","width":1100,"height":520,"caption":"1,200 MLD pumping station, sited at NEOM desalination plant tank farm, and a culverted twin 2,000 mm dia. carbon steel potable water transmission system. The pumping station discharges through a 65 km twin 2,000 mm dia. transmission system to the High Point Reservoir, while a 37 km similar gravity twin transmission system conveys water to Gayal. Future provision within the pumping station will enable the later addition of three further piping systems to give an overall capacity of 2,100 MLD. Full infrastructure and electrical sub-stations and support facilities are provided at the pumping station site. The 100 km buried pre-cast culvert is sized to accommodate a third future 2,000 mm dia. pipeline and includes connection chambers, washout, and air release facilities. The scope includes system hydraulics, surge\/transient analysis and protection measures, and full instrumentation and control."},{"@type":"BreadcrumbList","@id":"https:\/\/www.ecgsa.com\/project\/water-transmission-system-from-oxagon-to-gayal\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ecgsa.com\/"},{"@type":"ListItem","position":2,"name":"Projects","item":"https:\/\/www.ecgsa.com\/project\/"},{"@type":"ListItem","position":3,"name":"Water Transmission System from OXAGON to GAYAL"}]},{"@type":"WebSite","@id":"https:\/\/www.ecgsa.com\/#website","url":"https:\/\/www.ecgsa.com\/","name":"ECG website","description":"Just another WordPress site","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.ecgsa.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.ecgsa.com\/wp-json\/wp\/v2\/project\/9670"}],"collection":[{"href":"https:\/\/www.ecgsa.com\/wp-json\/wp\/v2\/project"}],"about":[{"href":"https:\/\/www.ecgsa.com\/wp-json\/wp\/v2\/types\/project"}],"version-history":[{"count":1,"href":"https:\/\/www.ecgsa.com\/wp-json\/wp\/v2\/project\/9670\/revisions"}],"predecessor-version":[{"id":9673,"href":"https:\/\/www.ecgsa.com\/wp-json\/wp\/v2\/project\/9670\/revisions\/9673"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ecgsa.com\/wp-json\/wp\/v2\/media\/9672"}],"wp:attachment":[{"href":"https:\/\/www.ecgsa.com\/wp-json\/wp\/v2\/media?parent=9670"}],"wp:term":[{"taxonomy":"activity","embeddable":true,"href":"https:\/\/www.ecgsa.com\/wp-json\/wp\/v2\/activity?post=9670"},{"taxonomy":"country","embeddable":true,"href":"https:\/\/www.ecgsa.com\/wp-json\/wp\/v2\/country?post=9670"},{"taxonomy":"scope","embeddable":true,"href":"https:\/\/www.ecgsa.com\/wp-json\/wp\/v2\/scope?post=9670"},{"taxonomy":"sector","embeddable":true,"href":"https:\/\/www.ecgsa.com\/wp-json\/wp\/v2\/sector?post=9670"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}